The New UL Sauna Heater Standard Is Here. The Building Code Isn’t Ready.

By Arlene Scott
Correspondent, Research and Industry
- Published
- Reading time
- 12 min
SaunaNews is published by SaunaShare, Inc., which also runs SaunaShare.com and SaunaMarketplace.com, where we sell many of the products we write about. That experience may change what we write about and what we don't. Who owns SaunaNews
UL 60335-2-53 is the US adoption of the international sauna heater standard. Model codes still reference the old standard, manufacturers are mid-recertification, and inspectors may not know the difference.
In this story7 sections
On June 27, 2025, Underwriters Laboratories published ANSI/UL 60335-2-53, the US adoption of the international sauna heater safety standard used in Europe and most of the rest of the world.
The old standard, UL 875, remains active. The transition is happening model by model, lab by lab and jurisdiction by jurisdiction, and the building codes that inspectors actually enforce have not caught up.
What UL 875 actually required
UL 875 has governed electric sauna heaters in the United States for decades. The requirements are codified in the 2024 International Mechanical Code (IMC), Section 914, which remains the reference standard for building inspectors across most of the country. Under this framework, sauna heaters must be listed and labeled to UL 875. Room temperature at the thermostat sensor is capped at 194°F. The heat-sensing element must sit within six inches of the ceiling when it is not integral to the heater. Timer operation is limited to one hour. And a ventilation opening is required near the top of the door.
The practical effects went further. Industry observers, including consultants working directly with manufacturers on recertification, have documented the downstream consequences. Temperature sensors positioned above the stone basket routinely produced readings 20 to 50°F higher than the actual room temperature. High-temperature limiters tripped at conservatively low thresholds, causing nuisance shutoffs that left users waiting an hour or more for the heater to reset.
The IMC code requires a 4-by-8-inch opening near the top of the sauna door. But because UL 875’s high-temp limiter had such a low trip point, manufacturers’ US installation manuals separately instructed installers to bring supply air in below or behind the heater to cool the sensor and prevent nuisance shutoffs. That airflow scheme directed fresh air across the floor rather than to bathers at bench level, resulting in poor CO2 removal and stale air in many American saunas.
In practice, the standard made American saunas cooler and less accurate than their European equivalents. Experienced sauna users and builders frequently worked around the requirements to get something resembling a normal sauna experience, which arguably created more safety risk than the standard was supposed to prevent.
What UL 60335-2-53 changes
The new standard is a First Edition US adoption of IEC 60335-2-53, Edition 4.2, issued by the International Electrotechnical Commission in March 2021. A separate National Differences document covers all US-specific deviations from the international base text. Both were published June 27, 2025.
Confirmed from public primary sources
The new standard explicitly covers both electric sauna heaters and infrared cabins. UL 875 did not address infrared in the same unified framework, which left a growing product category in a regulatory gray area. That gap is now closed.
The US scope extends coverage to heaters up to 30kW. The IEC base text covers heaters up to 20kW. The US-specific expansion accommodates larger commercial installations.
UL 875 remains active. The new standard creates an additional certification path. It does not automatically retire the old one.
Credibly attributed to industry sources
According to industry observers and manufacturer consultations reported through late 2025, the most consequential practical changes are these:
Thermostat sensors can now be positioned over the seating area rather than above the heater. A sensor over the bench reads actual bather-level temperature instead of the superheated air directly above the stones.
High-temperature trip thresholds have been raised, which should reduce nuisance shutoffs.
With higher trip thresholds on the high-temp limiter, the manufacturer practice of directing supply air below or behind the heater to cool the sensor should no longer be necessary. This was never a code requirement per se (the IMC code vent is a 4-by-8-inch opening near the top of the sauna door), but it was baked into every US installation manual as a practical workaround for UL 875’s oversensitive limiter. Removing that need means ventilation can be designed for bather comfort and air quality rather than sensor protection.
The run-time timer extends from one hour to three hours, with a six-hour maximum under the IEC framework.
What has not changed
The towel test and overlimit switch requirements survive into the new standard. The towel test simulates a combustible material draped over the heater; the overlimit switch is a last-resort thermal cutoff.
The SaunaNews Sauna Recall Tracker lists the sauna heater, infrared room and other sauna recalls regulators have published since 2015.
There is also a notable caveat for prefabricated sauna kits and infrared cabins specifically: the new standard includes natural convective updraft ventilation requirements for these products that some industry experts argue enshrine poor ventilation practices rather than improve them.
What remains uncertain
Whether 257°F is now permitted in US-certified saunas is an open question. Prior IEC text explicitly noted that the 257°F limit was “not applicable (USA).” The current market reflects this ambiguity. Some manufacturers’ US documentation still stops at 194°F: Harvia’s US manual for its Xenio control unit lists a 104 to 194°F adjustment range, while Harvia’s European manual for the same controller runs to 230°F. HUUM’s US manual for its UKU controller, used with its SGS-listed heaters, allows a setpoint of up to 230°F; on the newer UKU 4.2, adding the optional bench sensor limits the setpoint to 194°F. Until someone publishes a definitive reading of the paid National Differences document on this point, treat any blanket “257°F is now allowed in the US” claim with caution.
The building code gap
The 2024 International Mechanical Code, Section 914, still explicitly mandates UL 875. It still requires the 194°F ceiling. It still requires the sensor within six inches of the ceiling. It still requires the one-hour timer. The IMC is the model code used by building inspectors in most US jurisdictions. It updates on a three-year cycle and then must be adopted state by state, county by county, city by city.
This creates a compliance gap. A heater could be certified to the new UL 60335-2-53 standard, installed according to that standard’s more permissive allowances, and still technically fail a building inspection in any jurisdiction whose adopted code references UL 875. That is most jurisdictions today.
For builders, architects, and anyone pulling a sauna permit: the standard printed on your heater’s label determines which installation rules legally apply. A heater labeled UL 875 must be installed to UL 875 specs. Only a heater carrying the new UL 60335-2-53 mark, once its manufacturer completes recertification, will qualify for the new allowances. And even then, a building inspector working from an older adopted code may still cite the old requirements.
Talk to your Authority Having Jurisdiction (AHJ) before you build. Ask which standard they recognize. Get it in writing if you can.
The manufacturer recertification race
Some Harvia North American product lines still reference UL 875 for US listings while simultaneously citing CSA E60335-2-53 for Canadian listings. HUUM has taken a different path entirely, using SGS rather than UL directly as its Nationally Recognized Testing Laboratory. Both are OSHA-recognized, both are legitimate, but the distinction confuses consumers who see a non-UL mark and assume something is wrong.
UL is not the only lab authorized to certify products to UL-numbered standards. OSHA recognizes multiple NRTLs, including SGS, Intertek, Eurofins, and TUV SUD, among others. A heater does not need a literal UL logo to be compliant. It needs certification to the applicable standard by any recognized NRTL. When shopping for a sauna heater, the relevant question is: which specific standard is this specific model certified to, and by which lab?
Recertification under the new standard takes time and money. Each manufacturer must individually submit and retest each model. Some products may temporarily go out of stock during this process. And retrofitting an existing UL 875-labeled heater (relocating a temperature sensor, for instance) voids the UL listing. UL marks are controlled assets. They cannot be reissued by homeowners or added post-market. If your heater carries a UL 875 sticker, that is the standard it lives under, regardless of what the new rules allow for newly certified products.
Harvia’s Fenix launch is an early example of this transition pressure on controls as well as heaters: it is the first Harvia controller line being marketed around the new standards era, with Xenio gradually phased down in parallel. We break down the pricing and migration confusion in our companion report on Harvia’s Xenio-to-Fenix shift.
European manufacturers who already build to IEC 60335-2-53 face a lower certification hurdle for the US market under the new standard. Even with tariff pressures on EU imports, we may see more European heater brands entering North America. Meanwhile, domestic and Canadian manufacturers get a less restrictive testing framework that should reduce development costs over time.
The regulatory traffic runs both ways. In February 2026, CEN published EN 18164:2026, the first pan-European standard for public sauna rooms. EN 18164 explicitly excludes electrotechnical aspects and defers to EN 60335-2-53 for the heater itself. For any US manufacturer contemplating a European push, that means a single IEC-rooted heater safety standard now covers both markets, while European room-level construction, ventilation, and slip-resistance rules become the incremental documentation burden.
Remote start, smart controls, and the door switch
Separate from but running parallel to the standards transition, remote-start safety is becoming formalized across the industry. Current installation documentation from Harvia, Helo/Sauna360, and others reflects a consistent requirement: when a heater can be activated from outside the room via an app or remote control, a door interlock switch must be part of the installation. If the door is not properly closed, the safety circuit prevents the heater from energizing.
This is not a new UL clause published as part of the 60335-2-53 rollout. It is a design philosophy already embedded in current products and manuals, consistent with the direction of the new standard’s more software-safety-focused framework. For commercial installations, emergency shut-offs accessible both inside and outside the sauna room are increasingly standard practice, though specific requirements vary by jurisdiction.
A note on the UL 875 Tenth Edition
UL published a Tenth Edition of UL 875 in July 2024. Some industry coverage treated this as a significant update. It was not. The public summary of changes shows alignment with UL 4200A for products containing button and coin cell batteries (relevant as sauna controls incorporate wireless remotes), removal of a reference to UL 6059 for switches, updates to referenced standards in Section 3, and editorial cleanup. This was a maintenance revision, not a performance overhaul.
Questions to ask a dealer
If you are shopping for a sauna heater today, ask your dealer:
Is this specific model certified to UL 875 or UL 60335-2-53? The answer determines what installation rules apply. Which NRTL performed the certification? UL, SGS, Intertek, and others are all legitimate. Has the manufacturer completed recertification under the new standard, or is this a UL 875-era product? If it is still UL 875, the old rules (194°F cap, one-hour timer, sensor above the heater) apply to your installation regardless of what the new standard allows.
For those who previously relocated a temperature sensor to a more practical position (a common workaround in the enthusiast community), the new standard technically validates that sensor placement going forward, but only on newly certified heaters. If your existing heater carries a UL 875 label, moving the sensor still voids the listing.